If the VES-3600 Advanced Signal Processing option is authorized by your ME'scope license, the following Acoustics commands are enabled in the Data Block and Shape Table windows.
Check Help | About to verify authorization of this option.
The following columns are added to the M#s spreadsheet in a Data Block window.
Allows you to enter dB reference values that are used when dB is chosen for the Vertical Axis Scaling box. For Linear quantities (such as SPL), dB units are defined as;
Linear dB Units = 20 log10 (magnitude / dB Reference value)
For Power quantities (such as Sound Power & Intensity), dB units are defined as;
Power dB Units = 10 log10 (magnitude / dB Reference Value)
Indicates the type of acoustic weighting (A, B, C) applied to each measurement.
Used to enter a text name for each measurement belonging to an Acoustic source.
The following columns are added to the M#s spreadsheet in a Shape Table window.
Indicates the type of acoustic weighting applied to each measurement
Used to enter a text name for each measurement belonging to an acoustic source.